Why is a large refrigerant leak potentially dangerous?

Why is a large refrigerant leak potentially dangerous?

Are you worried about a potential ac Freon leak? If your home air conditioning unit has stopped working or no longer cools when you turn it on, then there may be something wrong with your Freon.

MYTH : AC Freon must be charged every spring.

It’s a common myth that freon is slowly depleted through air conditioning use. Instead, a freon leak is most often caused by small puncture holes that allow the gas-liquid to escape. Other causes can include poor installation, factory defects in your unit, or formic acid or formaldehyde corrosion of the metal.

How can you spot air conditioning freon leaks?

Freon leaks can get a lot worse as time goes by. Just like an inflatable bed or beach ball, the hole often starts as a pinhole leak and becomes a bigger problem if not stopped. Bert’s Inc an expert air conditioning repair technician can detect these tiny holes by observing tiny bubbles in the evaporator coils. This location is where freon leaks are most often spotted.

Health and environmental effects of Freon.

Freon is certainly a health hazard. Freon is a toxic substance, and for this reason, freon leaks should be handled by an expert repair technician. Freon leaks deplete the ozone layer and is unsafe for the environment. The biggest concern with freon leaks is assuring that no freon enters the airflow inside the interior of your home. If you start to experience a foul-smelling odor escaping your HVAC system during operation, then you could have a freon leak. Call Bert’s Inc Immediately!

Common causes and solutions for A/C freon leaks.

Freon leaks are not as common as you may think. A brand new air conditioning unit has the potential to leak freon if not installed properly. In the beginning, a good air conditioning repair technician rules out freon leaks by testing the system’s soldering.

The second most common thing that can lead to freon leaks is damage. Any sort of damage your air conditioning unit can cause separate components to fail. Be careful with your lawn mowers and trimers around the outdoor ac unit.

The most common cause of ac freon leak is likely erosion from either formic acid or formaldehyde corrosion. Small holes are formed when the acid eats away at the metal and the unit eventually releases freon. This can be repaired by replacing the separate components such as the coils or installing a new air conditioning unit depending on the damage.

Finally, the last major cause of freon leaks are factory defects. There’s no way for you to know your brand new air conditioning unit is defective when it comes to holding freon, unless you consult an expert air conditioning repair technician. Not to mention, most air conditioning manufacturing companies void the warranty if repairs are made by someone other than a trained technician, so get in touch with an air conditioning repair company if you suspect your brand new ac is leaking freon. It’s not uncommon to find freon leaks 5 to 10 years after the initial air conditioning installation!

Do you need someone to find and fix an ac freon leak? Get in touch with an expert air conditioning repair technician at Bert’s Inc. We offer emergency 24/7 ac repair.

Does a Freon leak mean I need a new A/C Unit?

Why is a large refrigerant leak potentially dangerous?

Commercial coolers are no stranger to slight wear-and-tear damage over time. While most of these can be quickly resolved and prevented with regular maintenance, other types of damage, such as leaks, can go undetected until they pose serious problems. Chief among these issues is health concerns, with the most alarming being Freon poisoning.

Commercial coolers can leak up to 30% of their charge throughout the year. The best way to prevent and repair this is through regular maintenance. Using manifold gauges and maintenance leak testing, professional technicians can detect changes in the Freon pressure early on, along with shifts in evaporator and condenser temperatures. Freon levels need to be regularly monitored to detect harmful leaks early on.

What is Freon and why is it dangerous?

Freon is a tasteless, odourless gas, making it virtually undetectable to those potentially exposed to it. Exposure may be caused by a limited spill on the skin or breathing near an open container. Freon poisoning can quickly escalate when deeply inhaled, which cuts off the oxygen supply to the lungs.

Other symptoms of Freon poisoning include dizziness, headaches, irritation to the eyes, nose, and throat, and palpitations. In the long run, this can result in breathing problems, fluid build-up in the lungs, organ failure, and even sudden death.

Freon is a common source of leaks in commercial coolers, so it’s important to detect pressure changes right away and repair any issues before harmful exposure occurs.

Other Common Causes of Commercial Cooler Leaks

What causes commercial coolers to leak? Aside from Freon gas leaks, other installation and performance issues, as well as damage to certain parts, can cause harmful leaks that reduce the overall function of the cooling unit. These require urgent repair, as well as early detection during a routine maintenance service:

1. Compressor discharge vibrations

Commercial coolers typically vibrate at a low but steady rate while running. But while system vibrations are normal, lines or fittings may break in the long run, especially if vibrations occur on or around the compressor discharge lines.

2. Corrosion

Certain liquids or condensation can corrode delicate parts of a commercial cooler, which causes irreversible damage and eventual breakdown. That’s because copper — the most common component of commercial cooler parts — will easily corrode when exposed to acidic chemicals and materials. Evaporators made of copper will quickly develop pinhole leaks as a result.

Using harsh chemicals to clean a commercial cooler can corrode the delicate parts, such as the condenser and coils. Similarly, condensation close to certain parts like the compressor rack can also cause damaging leaks.

3. Loose fittings

A common issue with a simple fix, loose fittings will easily cause leaks in any number of parts of a commercial cooler. Just as well, over-tightening fittings can damage them and cause cracks to the unit, and eventually, leaks as these fittings and surfaces deform due to the increased pressure.

4. Improper brazing

Alloy and metal brazing are used to weld together the different components and delicate parts of a commercial cooler. But even the slightest misstep in the brazing process or damage to the connections can result in faulty connections, and inevitably leaks.

A suboptimal commercial cooler model may employ the incorrect brazing alloy to cut down manufacturing and sale costs. Similarly, the brazing technique may be faulty, such as the heating temperature improperly distributed throughout the components, which reduces the efficacy of the melting process. These errors in brazing can result in faulty connections between essential components, making them prime for leaks.

Commercial coolers are fitted with multiple tubings for feeding water lines and holding pressure changes. But not all tubings were created equal — and each type of cooler is compatible with different kinds of tubing.

Typically, commercial coolers are built with either copper or steel alloys. However, these two metals shouldn’t come in contact with each other because this can compromise connections. When copper and steel tubings rub through their protective tubing walls, leaks can occur due to the tension and pressure between these metals.

6. Stress on tubings

Just as different types of tubing cannot safely come in contact with each other, each tubing requires proper fit and support upon connection. When left unsupported, copper tubing will sag at pressure points, especially 90-degree turns. Over time, this pressure can cause the tubing to break, which results in leaks.

7. Missing valve caps and seals

Tubings, fittings, and brazing are responsible for holding and welding together the different parts of a commercial cooler. The intricate connections they make possible are securely fastened together by seals and valve caps.

Similarly, valve caps and seals also help isolate different connections and mechanisms to prevent contact between various parts and metals. When any valve cap, seal, or o-ring goes missing, leaks can occur and may affect the performance of commercial coolers.

8. Retrofitting refrigerant issues

Commercial coolers require specific types of oil or refrigerant to run and provide optimal storage and cooling conditions for inventory. But because refrigerant eventually runs out or requires retrofitting, performance issues may arise. In particular, leaks and damage can occur if the cooler is retrofitted with a different or incompatible type of refrigerant. This can result in swelling and increased pressure.

9. Thermal stress

Commercial coolers are designed for optimal climate control. Holding steady cooling temperatures guarantee long-term food safety. But the reality is, frequent opening and closing mechanisms and regular wear-and-tear may cause temperatures to fluctuate.

Why is a large refrigerant leak potentially dangerous?

Fluctuating temperatures cause piping in coolers to expand and contract. However, the compact arrangement of fittings often leaves little room for expansion. Continuous expansion can then result in damage, as the pressure on fittings supporting pipes causes them to break.

Alternatively, while they may retain their shape and function in the short-term, the constant fluctuation may impact the efficacy of gasket seals, which eventually causes them to break down.